Industrial Transformers
K-Rated Transformers
Magnetic Control & Electricals K-Factor Transformers address the problems caused by non-linear loads and harmonics. They also compensate for stresses on a transformer’s winding insulation which prevents insulation…
-
High EfficiencyLower energy losses
-
Reliable PerformanceLong service life
-
IEC CertifiedMeets global standards
Price on Request
-
Free ShippingOn orders over £500
-
Secure Payment100% secure checkout
-
2 Year WarrantyManufacturer warranty
Product Overview
Magnetic Control & Electricals K-Factor Transformers address the problems caused by non-linear loads and harmonics. They also compensate for stresses on a transformer’s winding insulation which prevents insulation breakdown and premature failure. The net result is longer transformer life.
| Voltage Range | Low Voltage (≤ 1kV) |
|---|---|
| Cooling Type | Dry Type |
| Brand | Magnetic Control |
| Rating | Neutral rated for 200% current |
| Construction | Copper or aluminium wound |
| Standards | ANSI / IEEE C57.12.01 |
What is K-factor?
- K-factor is a value how much transformer can withstand harmonics
without increase in maximum temperature value.A standard transformer
cannot handle harmonics due to non linear loads.When harmonics enter
into the transformer the core gets saturated as a result it produces
lots of heat and failure of transformers. - K-rating differs according to harmonic levels like K-1,K-4,K-7,K-13,K-20.
FEATURES OF MAGNETIC COTROLS K- RATED TRANSFORMER
- Magnetic and Controls manufactures transformers based on the current spectrum considering the de-rating factor and oversizing factor.
- Magnetic and Controls manufacturer K-rated transformer in compliance with ANSI/IEEE C57.12.01
- Transformer can be designed with both copper and aluminium wound
- Neutral to withstand 200% current
- High grade core material and 99.99% electrolyte conductor material
- High harmonic current carrying capacity with low eddy current loss
- Impedance with compliance to IS 2026 standards and noise attenuation
SALIENT FEATURES OF MAGNETIC CONTROLS K- RATED TRANSFORMER
- High thermal withstanding capacity
- Low losses
- High Efficiency
- High & Low Voltage Overload Alarms
- Over Temperature Alarms
- Customer Friendly Design
- Rigged Construction
- Enclosures are as per IP or NEMA Standards
- Mitred Core Joints to K Rated Standards
- Operating Temperature: Ambient 0°C to 55°C
- Storage Temperature: Ambient 0°C to 55°C
- 60 Hz Operating Range: 57 – 63 Hz and also 50 Hz as per customer request
- Relative Operating Humidity : 90% Non Condensing
Technical Specifications
- Voltage Range
- Low Voltage (≤ 1kV)
- Cooling Type
- Dry Type
- Brand
- Magnetic Control
- Rating
- Neutral rated for 200% current
- Construction
- Copper or aluminium wound
- Standards
- ANSI / IEEE C57.12.01